Tektronix Oscilloscope Manual
. MSO2000B and DPO2000B Series Oscilloscopes User Manual.P077072400. 077-0724-00.
MSO2000B and DPO2000B Series Oscilloscopes User Manual www.tek.com 077-0724-00. Copyright © Tektronix. All rights reserved. Licensed software products are owned by Tektronix or its subsidiaries or suppliers, and are protected by national copyright laws and international treaty provisions. Tektronix products are covered by U.S. And foreign patents, issued and pending. Information in this publication supersedes that in all previously published material.
Warranty Tektronix warrants that the product will be free from defects in materials and workmanship for a period of five (5) years from the date of original purchase from an authorized Tektronix distributor. If the product proves defective during this warranty period, Tektronix, at its option, either will repair the defective product without charge for parts and labor, or will provide a replacement in exchange for the defective product. Warranty Tektronix warrants that this product will be free from defects in materials and workmanship for a period of one (1) year from the date of shipment.
If any such product proves defective during this warranty period, Tektronix, at its option, either will repair the defective product without charge for parts and labor, or will provide a replacement in exchange for the defective product. Warranty Tektronix warrants that the product will be free from defects in materials and workmanship for a period of one (1) year from the date of original purchase from an authorized Tektronix distributor.
If the product proves defective during this warranty period, Tektronix, at its option, either will repair the defective product without charge for parts and labor, or will provide a replacement in exchange for the defective product. Table of Contents Table of Contents General safety summary.Compliance Information. Table of Contents Trigger Setup. Triggering Concepts. General safety summary General safety summary Review the following safety precautions to avoid injury and prevent damage to this product or any products connected to it.
To avoid potential hazards, use this product only as specified. Only qualified personnel should perform service procedures.
To avoid fire or personal injury Use proper power cord. General safety summary Terms in this manual These terms may appear in this manual: WARNING.
Tektronix Oscilloscope Manuals
Warning statements identify conditions or practices that could result in injury or loss of life. Caution statements identify conditions or practices that could result in damage to this product or other property. Symbols and terms on the product These terms may appear on the product: DANGER indicates an injury hazard immediately accessible as you read the marking. EN 61000-3-2:2006. AC power line harmonic emissions EN 61000-3-3:1995. Voltage changes, fluctuations, and flicker European Contact.
Tektronix UK, Ltd. Western Peninsula Western Road Bracknell, RG12 1RF United Kingdom This product is intended for use in nonresidential areas only. Use in residential areas may cause electromagnetic interference. Compliance Information CISPR 11:2003.
Radiated and Conducted Emissions, Group 1, Class A, in accordance with EN 61326-1:2006 and EN 61326-2-1:2006. MSO2000B and DPO2000B Series Oscilloscopes User Manual. Compliance Information Safety Compliance EC Declaration of Conformity – Low Voltage Compliance was demonstrated to the following specification as listed in the Official Journal of the European Communities: Low Voltage Directive 2006/95/EC. EN 61010-1: 2001. Safety requirements for electrical equipment for measurement control and laboratory use. Compliance Information Pollution Degree Pollution Degree 2 (as defined in IEC 61010-1). Note: Rated for indoor use only.
Installation (Overvoltage) Category Descriptions Terminals on this product may have different installation (overvoltage) category designations. The installation categories are: Measurement Category IV. For measurements performed at the source of low-voltage installation. Measurement Category III.
This symbol indicates that this product complies with the applicable European Union requirements according to Directives 2002/96/EC and 2006/66/EC on waste electrical and electronic equipment (WEEE) and batteries. For information about recycling options, check the Support/Service section of the Tektronix Web site (www.tektronix.com).
Preface Preface This manual describes the installation and operation of the following oscilloscopes: MSO2024B MSO2022B MSO2014B MSO2012B MSO2004B MSO2002B DPO2024B DPO2022B DPO2014B DPO2012B DPO2004B DPO2002B Key Features MSO2000B and DPO2000B series oscilloscopes can help you verify, debug, and characterize electronic designs. Preface Conventions Used in This Manual The following icons are used throughout this manual. Front panel power Network Sequence Step Connect power MSO2000B and DPO2000B Series Oscilloscopes User Manual. Preface MSO2000B and DPO2000B Series Oscilloscopes User Manual. Before Installation Unpack the oscilloscope and check that you received all items listed as standard accessories. The following pages list recommended accessories and probes, instrument options, and upgrades.
Check the Tektronix Web site (www.tektronix.com) for the most current information. Standard Accessories. Installation Standard Accessories (cont.) Tektronix part Accessory Description number Power cord North America (Option A0) 161-0348-00 161-0343-00 Universal Euro (Option A1) United Kingdom (Option A2) 161-0344-00 Australia (Option A3) 161-0346-00 Switzerland (Option A5) 161-0347-00 Japan (Option A6) 161-0342-00 161-0341-00 China (Option A10). 0.1 inch header pins TekVPI probes that work Visit the Oscilloscope Probe and Accessory Selector with MSO/DPO2000B Series Tool on the Tektronix website at www.tektronix.com. Oscilloscopes Note: These probes require the use of the TekVPI external power adapter listed below. MSO/DPO2000B and MSO/DPO2000 series Oscilloscopes Application Module oscilloscopes Installation The MSO2000B and DPO2000B series oscilloscopes work with multiple optional probes.
(See page 8, Connecting Probes.) Check the Tektronix Web site (www.tektronix.com) for the most current information. Related Documentation Accessory Description Tektronix part number.
. TBS1000, TBS1000B/TBS1000B-EDU, TDS1000B/TDS2000B, TDS1000C-EDU/TDS2000C, and TPS2000B Series Digital Storage Oscilloscope Declassification and Security Instructions.P077077101. 077-0771-01. TBS1000, TBS1000B/TBS1000B-EDU, TDS1000B/TDS2000B, TDS1000C-EDU/TDS2000C, and TPS2000B Series Digital Storage Oscilloscope Declassification and Security Instructions www.tektronix.com 077-0771-01. All rights reserved. Licensed software products are owned by Tektronix or its subsidiaries or suppliers, and are protected by national copyright laws and international treaty provisions. Tektronix products are covered by U.S.
Tektronix Oscilloscope Programming Manual
And foreign patents, issued and pending. Information in this publication supersedes that in all previously published material. Table of Contents Preface.Memory devices Volatile memory devices. Volatile memory devices (TBS1000B & TBS1000B-EDU).Nonvolatile memory devices.Nonvolatile memory devices container (TBS1000B & TBS1000B-EDU).Data export devices.Clear and sanitize procedures Clear the flash memory. Table of Contents Declassification and Security Instructions. Instrument code and calibration settings reside in nonvolatile flash memory. Instrument setups and reference waveforms may also be stored in flash memory or on USB drives connected to the instrument.
If you have any questions, contact the Tektronix Technical Support Center at www.tektronix.com/support. Reference The procedures in this document are written to meet the requirements specified NISPOM, DoD 5220.22–M, Chapter 8. Preface Required documents To perform the procedures in this document, you will need to have access to the manuals listed below. These manuals are available on the Tektronix Web site at www.tektronix.com/downloads.
TBS1000 Series Digital Storage Oscilloscope Service Manual (Tektronix ■. Preface Terms used in this document The following terms may be used in this document: Clear.
This removes data on media/memory before reusing it in a secured ■ area. All reusable memory is cleared to deny access to previously stored information by standard means of access. Preface Device terms The following terms are used with the memory devices in this document: User data.
Describes the type of information stored in the device. Refers to ■ waveforms or other measurement data representing signals connected to the instrument by users. User settings. Memory devices Volatile memory devices The volatile memory devices for the TBS1000B and TBS1000B-EDU products are listed in the Volatile memory devices (TBS1000B & TBS1000B-EDU) page 3 section. SDRAM 512 K Type and size 512 K X 32 Function Acquisition memory for holding and processing waveforms, and processor system RAM Type of user information Both user data and user settings stored. Memory devices Volatile memory devices (cont.) Data input method User input Location Main Acquisition board User accessible To clear Remove the battery from the board. Process to sanitize Remove the battery from the board.
USB2 Type and size USB 2.0 OTG host/peripheral controller, 8 K X 16 RAM Function Contains USB controller program and data memory Type of user information. Volatile memory devices (cont.) Memory devices Volatile memory devices (TBS1000B & TBS1000B-EDU) This section lists the volatile memory devices for the TBS1000B and TBS1000B- EDU products. These products have a different hardware platform than the TBS1000, TDS1000B/TDS2000B, TDS1000C-EDU/TDS2000C, and TPS2000B Series. Memory devices Nonvolatile memory devices The nonvolatile memory devices for the TBS1000B and TBS1000B-EDU products are listed in the Nonvolatile memory devices container (TBS1000B & TBS1000B-EDU) on page 5 section. Flash Type and size FLASH, 8 M X 8, 4 M X 16 Function Holds instrument firmware, current setup, saved setups, saved reference waveforms, hard copy image files, and calibration constants.
Nonvolatile memory devices (cont.) Memory devices Nonvolatile memory devices container (TBS1000B & TBS1000B-EDU) This section lists the nonvolatile memory devices for the TBS1000B and TBS1000B-EDU products. These products have a different hardware platform than the TBS1000, TDS1000B/TDS2000B, TDS1000C-EDU/TDS2000C, and TPS2000B Series. Nand flash Type and size 2 G bit (256 X 8). Memory devices Data export devices USB host port Type and size USB host port Function Supports removable USB flash drive. User storage of reference waveforms, screen images, and instrument setups. Method of modification Directly Data input method Save Location Front panel To disable Files can be deleted or overwritten on the oscilloscope or a PC. Clear and sanitize procedures Clear the flash memory This procedure does not erase or change factory calibration constants.
Push the front panel DEFAULT SETUP button to recall the default setup. Push the front panel SAVE/RECALL button. Push the Action option (side bezel) button until Save Setup is selected. Clear and sanitize procedures 20. Push the front panel PRINT button to overwrite the hard copy image file with an image that does not contain any useful information.
Power off the oscilloscope, and then power on the oscilloscope to complete the process. Compact flash card (TPS oscilloscopes only) Remove the compact flash card and return the instrument to Tektronix for repair. After removal of the compact flash card, refer to your company's internal policies regarding handling or disposal of the compact flash card. Clear or sanitize a non-functional instrument Declassification and Security Instructions.